Strona 1 - MS3580 QuantumT

METROLOGIC INSTRUMENTS, INC.MS3580 QuantumT™Installation and User's Guide

Strona 2

6 INTRODUCTION Mounting Specifications and Stand Assembly Pedestal Stand Figure 4. Pedestal Stand Assembly Optional Flex Stand Figure 5. Asse

Strona 3 - ABLE OF CONTENTS

7INTRODUCTION Mounting Specifications and Stand Assembly Optional Flex Stand Figure 6. Mounting Hole Detail for the Flex Stand Base Plate (Opti

Strona 4

8 INSTALLATION RS232, RS232 TTL, Light Pen or Laser Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink

Strona 5

9INSTALLATION IBM 46xx or OCIA 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the

Strona 6

10 INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on t

Strona 7

11INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin sock

Strona 8

12 INSTALLATION Full Speed or Low Speed USB 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socke

Strona 9

13SCANNER OPERATION Configurable Primary and Secondary Scan Pattern Modes There are two configurable scan pattern modes available with the MS35

Strona 10 - INTRODUCTION

14 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED For illustration purposes the un

Strona 11

15SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED For illustration purposes the

Strona 12 - INSTALLATION

Copyright © 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, tra

Strona 13

16 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE ENABLED For illustration purposes the un

Strona 14

17SCANNER OPERATION Configurable Button Functions 5. To scan and transmit additional bar codes, repeat steps 2 through 4. 6. The primary sca

Strona 15

18 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE DISABLED For illustration purposes the u

Strona 16

19SCANNER OPERATION Audible Indicators When the MS3580 is in operation, it provides audible feedback to indicate the status of the scanner. Eigh

Strona 17 - SCANNER OPERATION

20 SCANNER OPERATION Visual Indicators The QuantumT is equipped with a blue and white LED that indicates the scanner’s state and the status of th

Strona 18

21SCANNER OPERATION Failure Mode Indicators Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsy

Strona 19

22 SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 14. MS35

Strona 20

23SCANNER OPERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 15. MS35

Strona 21

24 SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15 .19 .25

Strona 22

25SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15 .19

Strona 23

ii TABLE OF CONTENTS Introduction Product Overview ... 1 S

Strona 24

26 SCANNER OPERATION IR Activation Range* QuantumT‘s default power save mode† is Laser OFF. This power save mode turns the laser off after a con

Strona 25

27TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3

Strona 26

28 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan (the whi

Strona 27

29TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces During power up the unit beeps 3 times. There is a non-volatile RAM f

Strona 28

30 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanne

Strona 29

31DESIGN SPECIFICATIONS MS3580 Operational Light Source: Visible Laser Diode (VLD) @ 650 nm Laser Power: 1.1 mW Normal Depth of Field: 19 m

Strona 30

32 DESIGN SPECIFICATIONS MS3580 Mechanical Width: 63 mm (2.48") Depth: 50 mm (1.97") Height: 68 mm (2.68") Weight: 6 oz (170 g

Strona 31 - TROUBLESHOOTING GUIDE

33APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER V

Strona 32

34 DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The sca

Strona 33

35DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA USB RS232* OR RS232 TTL LIGHT PEN IBM 46XXKBWLASER EMULATIONExpanded ID “]

Strona 34

iii TABLE OF CONTENTS Troubleshooting Guide ... 27 Design Speci

Strona 35 - DESIGN SPECIFICATIONS

36 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA USB RS232* OR RS232 TTL LIGHT PEN IBM 46XXKBWLASER EMULATIONTransmit UPC-A

Strona 36

37DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA USB RS232* OR RS232 TTL LIGHT PEN IBM 46XXKBWLASER EMULATIONNixdorf ID 

Strona 37 - APPLICATIONS AND PROTOCOLS

38 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT OCIA USB RS232* OR RS232 TTL LIGHT PEN IBM 46XXKBWLASER EMULATIONSupplements ar

Strona 38

39UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic’s new line of Flash- based scanners. This progra

Strona 39

40 SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS3580 scanner interfaces terminate to a 10-pin modular socket. The serial # la

Strona 40

41SCANNER AND CABLE TERMINATIONS MS3580-11 IBM 468X/469X MS3580-9 OCIA Pin Function Pin Function 1 Ground 1 Ground 2 RS232 Transmit Output 2

Strona 41

42 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable MLPN 54-54000x -3 straight Pin Function 1

Strona 42

43SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 54-54002x -3 Pin Function 1 Keyboard C

Strona 43 - MLPN 54-54014) are required

44 LASER AND PRODUCT SAFETY Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in haz

Strona 44 - Scanner Pinout Connections

45LASER AND PRODUCT SAFETY Notices This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part

Strona 45

1INTRODUCTION The QuantumT™ is a hands-free, omnidirectional bar code scanner with optional single-line scanning capabilities. It utilizes the

Strona 46 - MLPN 54-54020

46 LIMITED WARRANTY The MS3580 QuantumT™ scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS3580 Quantum

Strona 47

47PATENTS Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No.; 5,216,232; 5

Strona 48 - LASER AND PRODUCT SAFETY

48 INDEX A AC ...2, 8–12 Accessories ...2, 3 Adapter...

Strona 49

49INDEX MetroSet2...39 Mode of Operation Button ...18 Primary ...

Strona 50 - LIMITED WARRANTY

50 CONTACT INFORMATION AND OFFICE LOCATIONS CORPORATE HEADQUARTERS NORTH AMERICA EUROPEAN, MIDDLE EAST & AFRICAN HEADQUARTERS USA, New Jers

Strona 52

June 2005 Printed in the USA 00-05090B

Strona 53

2 INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description MS3580 QuantumT Omni \ Single-Line Scanner 00-02026 QuantumT Om

Strona 54

3INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description 54-54002x-3 Keyboard Wedge PowerLink Cable 2.1 m (7 ft.) straigh

Strona 55

4 INTRODUCTION Scanner Components Figure 1. Scanner Components ITEM NO. DESCRIPTION 1 Red Output Window (Laser Aperture) 2 Pin Hole for Cable

Strona 56 - Printed in the USA

5INTRODUCTION Caution and Serial Number Labels Figure 2. Cable Removal 1. Locate the small ‘pin-hole’ on the side of the QuantumT near the